3GPP TS 27.007 AT COMMANDS
77
HSPA+ AT Commands Reference Guide
<ber>
Bit error rate (in percent)
0
Less than 0.2%
1
0.2% to 0.4%
2
0.4% to 0.8%
3
0.8% to 1.6%
4
1.6% to 3.2%
5
3.2% to 6.4%
6
6.4% to 12.8%
7
More than 12.8%
99
Not known or not detectable
Notes
Reference: 3GPP TS 27.007.
Indicator Control +CIND
Set command controls the registration state of ME indicators, in order to automatically send the +CIEV URC,
whenever the value of the associated indicator changes. The supported indicators (<descr>) and their order
appear from test command AT+CIND=?.
Read command returns the current value of ME indicators, in the format:
+CIND: <ind>[,<ind>[,…]]
Note: The order of the values <ind>s is the same order appears from test command AT+CIND=?
Test command returns pairs, where string value <descr> is a description (maximum of 16 characters) of the
indicator and compound value is the supported values for the indicator, in the format:
+CIND: ((<descr>, (list of supported <ind>s))[,(<descr>, (list of supported <ind>s))[,…]])
where:
<descr>
Indicator names as follows (along with their <ind> ranges).
“battchg”
Battery charge level.
<ind>
Battery charge level indicator range .
0‐5
99
Not measurable.
“signal”
Signal quality.
<ind>
Signal quality indicator range.
0‐7
99
Not measurable.
“service”
Service availability.
<ind>
Service availability indicator range.
0
Not registered to any network.
1
Registered.
“sounder”
Sounder activity.
<ind>
Sounder activity indicator range.