Syntax, Parameters and values, Notes – Synaccess Networks NP-0801DTM User Manual

Page 219: Examples

Advertising
background image

CUSTOM AT COMMANDS 

 

 

219 

HSPA+ AT Commands Reference Guide

 

<CR><LF> 

. . .  

#SCFG: <connId6>,<cid6>,<pktsz6>,<maxTo6>,<connTo6>,<txTo6> 

<CR><LF> 

Test command returns the range of supported values for all the subparameters 

Syntax 

Command 

Command type 

AT#SCFG=<connId>,<cid>,<pktSz>,<maxTo>,<connTo>,<txTo> 

Set 

AT#SCFG? 

Read 

AT#SCFG=? 

Test 

Parameters and Values 

Note

: Values are automatically saved in non‐volatile memory. 

<connId> 

Socket connection identifier.

 

1‐6 

 

<cid> 

PDP context identifier. 

Specifies the GSM context. 

1‐5 

Numeric parameter which specifies a PDP context definition. 

<pktSz> 

Packet size used by the TCP/UDP/IP stack for data sending. 

Select default value of 300 automatically. 

1‐1500 

Packet size in bytes. 

<maxTo> 

Exchange timeout or socket inactivity timeout. If there is no data exchange within 
this timeout period the connection is closed. 

No timeout. 

1‐65535 

Timeout value in seconds. Default: 90

<connTo> 

Connection timeout; if cannot connect to the remote within this period, an error 
is raised. 

10‐1200 

Timeout value in hundreds of milliseconds. Default: 600

<txTo> 

Data sending timeout. After this period data is sent also if less than maximum 
packet size. 

No timeout. 

1‐255 

Timeout value in hundreds of milliseconds. Default: 50

Notes 

„

You must set the parameters with #SCFG before establishing a data connection using the AT+SGACT command. 

Examples 

at#scfg?

#SCFG: 1,1,300,90,600,50

#SCFG: 2,2,300,90,600,50

#SCFG: 3,2,250,90,600,50

Advertising