Syntax, Parameters and values, Notes – Synaccess Networks NP-0801DTM User Manual
Page 219: Examples

CUSTOM AT COMMANDS
219
HSPA+ AT Commands Reference Guide
<CR><LF>
. . .
#SCFG: <connId6>,<cid6>,<pktsz6>,<maxTo6>,<connTo6>,<txTo6>
<CR><LF>
Test command returns the range of supported values for all the subparameters
Syntax
Command
Command type
AT#SCFG=<connId>,<cid>,<pktSz>,<maxTo>,<connTo>,<txTo>
Set
AT#SCFG?
Read
AT#SCFG=?
Test
Parameters and Values
Note
: Values are automatically saved in non‐volatile memory.
<connId>
Socket connection identifier.
1‐6
<cid>
PDP context identifier.
0
Specifies the GSM context.
1‐5
Numeric parameter which specifies a PDP context definition.
<pktSz>
Packet size used by the TCP/UDP/IP stack for data sending.
0
Select default value of 300 automatically.
1‐1500
Packet size in bytes.
<maxTo>
Exchange timeout or socket inactivity timeout. If there is no data exchange within
this timeout period the connection is closed.
0
No timeout.
1‐65535
Timeout value in seconds. Default: 90.
<connTo>
Connection timeout; if cannot connect to the remote within this period, an error
is raised.
10‐1200
Timeout value in hundreds of milliseconds. Default: 600.
<txTo>
Data sending timeout. After this period data is sent also if less than maximum
packet size.
0
No timeout.
1‐255
Timeout value in hundreds of milliseconds. Default: 50.
Notes
You must set the parameters with #SCFG before establishing a data connection using the AT+SGACT command.
Examples
at#scfg?
#SCFG: 1,1,300,90,600,50
#SCFG: 2,2,300,90,600,50
#SCFG: 3,2,250,90,600,50