BECKHOFF EL9xxx User Manual

Page 26

Advertising
background image

Product overview

Technical data

Technical Data

EL9181

EL9182

EL9183

Technology

Potential distribution terminal

Number of separate potentials 2

8

1

Terminal points per potential

8

2

16

Nominal voltage

≤ 60 V

DC

Current load

max. 10 A (per terminal point)

Current consumption from E­
Bus

­

E­bus looped through

yes

Power contacts looped
through

yes (2 power contacts)

Diagnosis

­

Message to E­Bus

­

PE contact

no

Bit width in the process image 0

Electrical connection to
mounting rail

­

Electrical connection to power
contacts

­

Electrical isolation

­

Configuration

no address or configuration settings

Conductor types

solid wire, stranded wire and ferrule

Conductor connection

solid wire conductors: direct plug­in technique; stranded wire conductors and
ferrules: spring actuation by screwdriver

Rated cross­section

solid wire: 0.08…1.5 mm²; stranded wire: 0.25…1.5 mm²; ferrule: 0.14…0.75
mm²

Weight

approx.. 60 g

Permissible ambient
temperature range (during
operation)

0°C ... +55°C

Permissible ambient
temperature range (during
storage)

­25°C ... +85°C

Permissible relative humidity

95%, no condensation

Dimensions (W x H x D)

approx. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)

Mounting [

}

 60]

on 35 mm mounting rail conforms to EN 60715

Vibration/shock resistance

conforms to EN 60068­2­6/EN 60068­2­27

EMC resistance burst/ESD

conforms to EN 61000­6­2/EN 61000­6­4

Protect. class

IP 20

Installation pos.

variable, see chapter "Mounting of Passive Terminals [

}

 70]"

Approval

CE

Connection EL9181

Terminal point

Meaning

Indication

No.

1 ­ 8

1 ­ 8

Terminal points 1 ­ 8 are connected internally

9 ­ 16

9 ­ 16

Terminal points 9 ­16 are connected internally

EL9xxx