CRS-200

COMTECH COMMUNICATIONS CORPORATION

CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL PAGE 30

CONFIG: MANUAL AUTO[OFF]

OPTIONS REMOTE-CONTROL

MANUAL SELECT:

BRIDGE:02 BACKUP:02

CONFIG

The sub-branches available are:

MANUAL

This menu sub-branch permits the user to select which traffic

modem the switch should bridge or backup.

AUTO[ON]

This menu sub-branch permits the user to turn auto mode off or

on. The currently selected state is always shown on this menu.

OPTIONS

This menu sub-branch permits the user to set several operating

parameters of the switch that pertain to enabling or disabling the

availability of traffic modems, the reporting of faults and time

delays for responding to faults.

REMOTE

This menu sub-branch permits the user to define whether the

switch is being controlled locally, or remotely.

IMPORTANT NOTE: The switch may be monitored over the remote control bus

at any time. When in Local mode, however, configuration parameters may only

be changed through the front panel. Conversely, when in Remote mode, the unit

may be monitored from the front panel, but configuration parameters via may only

be changed remote control bus.

(CONFIG)

MANUAL

The user is prompted to enter which traffic modem the switch should

either bridge or backup. Both these selections are available when the
switch is in Manual mode (Auto is OFF), and using the

UP/DOWN keys

will scroll through all active traffic modems, skipping those that are

inactive. When in Auto mode, the switch controls backing up any

active traffic modem, based on its fault relay activity. Therefore, the

BACKUP selection is unavailable, and the BRIDGE selection is also

locked out when the switch is currently backing up a traffic modem

since the redundant modem is busy.

(CONFIG)

AUTO[OFF or ON]

Advertising