Comtech EF Data CRS-200 REDUNDANCY SWITCH User Manual

Page 53

Advertising
background image

Parameter

Command

Arguments for

Description of arguments

Response to Command

Query

Response to

Type

(Instruction

Command or

(note that all arguments are ASCII numeric codes, that is,

(target to controller)

(Instruction

query

Code and

Response to

ASCII codes between 48 and 57)

Code and

(target to

qualifier)

Query

qualifier)

controller)

CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL

PAGE 51

Switch Global

SGC=

21 bytes,

Command or Query. Global configuration of switch, in the

SGC= (message ok)

SGC?

SGC=Oaaaaaaa

Configuration

numerical

form: OaaaaaaaaaaBNNbbrrMSAssssssss where:

SGC? (received ok,

aaaBNNbbrrMS

O = Operating Mode - same as OPM= (1 bytes)

but invalid arguments

Assssssss

a = Active Modems - same as ACT= (10 bytes)

found)

(same format as

B = Bridge/Backup State – same as 1 half of BBU= (1 byte)

command

st

N = Selected TM Number - same as 2 half of BBU= (2

arguments)

nd

byte)

b = Backup Holdoff Time – same as BKH= (2 byte)

r = Restore Holdoff Time – same as RSH= (2 byte)

M = Modem Alarm Mask – same as MAM= (1 byte)

S = Switch Alarm Mask – same as SAM= (1 byte)

A = Audio Alarm Mask - same as AAM= (1 bytes)

s = 8 spare bytes

Config Store

CST=

1 byte,

Forces the unit to store the current modem configuration in

CST= (message ok)

CST?n,

Return the same

numerical, 0 to

Configuration Memory location defined by the one byte

CST? (received ok,

where

format as the

9

argument (0 to 9).

but invalid arguments

n is 0 to 9

MGC with

Example CST=4 (Store current config in location 4)

found)

The form:

WARNING: Use with caution! If the location already

CST= for a

contains data it will be automatically overwritten. If in

valid config,

doubt, query the location first.

and CST*

where no valid

config is found

Config Load

numerical, 0 to

Forces the switch to retrieve the Configuration Memory

CLD? (received ok, but

CLD=

1 byte,

Command only.

CLD= (message ok)

N/A

N/A

9

location defined by the one byte argument (0 to 9). and to

invalid arguments

re-program the switch with that stored configuration.

found)

CST* (message ok, but

the requested location

does not contain a

valid configuration)

Clear All Stored

CAE=

None

Command only

CAE= (message ok)

N/A

N/A

Events

Instructs the unit to clear all Stored Events

This command takes no arguments.