Comtech EF Data CRS-200 REDUNDANCY SWITCH User Manual

Page 50

Advertising
background image

CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL

PAGE 48

Parameter

Command

Arguments for

Description of arguments

Response to Command

Query

Response to

Type

(Instruction

Command or

(note that all arguments are ASCII numeric codes, that is,

(target to controller)

(Instruction

query

Code and

Response to

ASCII codes between 48 and 57)

Code and

(target to

qualifier)

Query

qualifier)

controller)

Set RTC

DAY=

6 bytes,

Command or query

DAY= (message ok)

DAY?

DAY=xxxxxx

Date

numerical

A command in the form ddmmyy, where; dd = day of the

DAY? (received ok,

(same format as

month, between 01 and 31, mm = month of the year,

but invalid arguments)

command

between 01 and 12 and yy = year, between 97 and 96

DAY* (message ok, but

arguments)

(1997 to 2000, then 2000 to 2096)

not permitted in current

Example: DAY=240457 would be April 24, 2057

mode

Set RTC

TIM=

6 bytes,

Command or query

TIM= (message ok)

TIM?

TIM=xxxxxx

Time

numerical

A command in the form hhmmss, indicating the time from

TIM? (received ok,

(same format as

midnight, where hh = hours, between 00 and 23; mm =

but invalid arguments)

command

minutes, between 00 and 59, and ss = seconds, between

TIM* (message ok, but

arguments)

00 and 59

not permitted in current

Example: TIM=231259 would be 23 hours, 12 minutes

mode

and 59 seconds from midnight.

Operating Mode

OPM=

1 byte,

Command or Query.

OPM= (message ok)

OPM?

OPM=x

numerical

Sets the operating mode:

OPM? (received ok,

(same format as

0 = manual mode

but invalid arguments)

command

1 = auto mode

OPM* (message ok, but

arguments)

not permitted in current

mode

Bridged or

BBU=

3 bytes,

Command or Query.

BBU= (message ok)

BBU?

BBU=xxx

Backup Modem

numerical

Sets or queries the bridged/backup state with the 1 byte,

BBU? (received ok,

(same format as

Number

followed by the selected TM to be acted on:

but invalid arguments)

command

st

1 byte: 0= bridged, 1= backup (this can only be set to 1

BBU* (message ok, but

arguments)

st

when in manual mode)

not permitted in current

last 2 bytes: 01-10 for selected TM

mode

Advertising