CRS-200

COMTECH COMMUNICATIONS CORPORATION

CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL PAGE 36

ALARMS MASKED: MODEM-TX

MODEM-RX

bbPSU-A PSU-B

``

MONITOR: STATUS SW-ALARM

STORED-EVENTS TM-CONFIGS

TM 02 IS BRIDGED BY RM

BACKUP HOLDOFF: 05 SEC

TM 02 IS BACKED UP BY RM

RESTORE HOLDOFF: OFF

STORED EVENTS: VIEW

CLEAR ALL (PRESS ENTER)

(INFO)

MASK (Alarm Mask Info)

This screen shows which alarms are currently masked. If an alarm is not

masked, a blank is displayed in the relevant screen position. Power

Supplies A and B cannot be masked at the same time, but are shown

together here to indicate their relative positions.

MONITOR

The user is prompted to select STATUS, SW-ALARM, STORED EVENTS, or TM-
CONFIGS using the

LEFT/RIGHT arrow keys, then to press ENTER.

(MONITOR) STATUS

This screen shows the current status of the switch. When the redundant

modem is not backing up any of the traffic modems, the display will

show which TM is currently being bridged by the RM. If Auto mode is

on, it will also show the backup holdoff should the bridged TM fail. If

Auto mode is off, the second line displays “OFF”. When the switch has

taken the bridged TM offline and replaced it with the RM (whether

done manually or automatically), the screen changes as shown below:

Now, the restore holdoff will be shown on the second line if Auto

mode is on.

(MONITOR) STORED EVENTS

The user is prompted to select VIEW or CLEAR ALL, using the
LEFT/RIGHT arrow keys, then to press ENTER.

Advertising