Comtech EF Data CRS-200 REDUNDANCY SWITCH User Manual
Page 52
Parameter
Command
Arguments for
Description of arguments
Response to Command
Query
Response to
Type
(Instruction
Command or
(note that all arguments are ASCII numeric codes, that is,
(target to controller)
(Instruction
query
Code and
Response to
ASCII codes between 48 and 57)
Code and
(target to
qualifier)
Query
qualifier)
controller)
CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL
PAGE 50
Restore Holdoff
RSH=
2 bytes,
Command or Query.
RSH= (message ok)
RSH?
RSH =xx
Time
numerical
Sets or queries the restore holdoff delay time used when
RSH? (received ok,
(same format as
auto mode prepares to return a previously faulted modem
but invalid arguments
command
back online due to another traffic modem’s failure:
found)
arguments)
02-99 = # of seconds after offline traffic modem lost its
RSH * (message ok, but
fault before it is put back online so that redundant modem
not permitted in current
can bridge the newly faulted modem
mode
Modem Alarm
MAM=
1 byte,
Command or Query.
MAM = (message ok)
MAM?
MAM =x
Mask
numerical
Sets or queries the modem alarm mask:
MAM? (received ok,
(same format as
0 = no faults masked
but invalid arguments
command
1 = Tx faults masked
found)
arguments)
2 = Rx faults masked
MAM * (message ok,
3 = Both Tx and Rx faults masked
but not permitted in
current mode
Switch Alarm
SAM=
1 byte,
Command or Query.
SAM = (message ok)
SAM?
SAM =x
Mask
numerical
Sets or queries the modem alarm mask:
SAM? (received ok,
(same format as
0 = no faults masked
but invalid arguments
command
1 = PSU A faults masked
found)
arguments)
2 = PSU A faults masked
SAM * (message ok, but
not permitted in current
mode
Audio Alarm
AAM=
1 byte,
Command or Query.
AAM = (message ok)
AAM?
AAM =x
Mask
numerical
Sets or queries the audio alarm mask:
AAM? (received ok,
(same format as
0 = no faults masked (audio enabled in response to any
but invalid arguments
command
fault)
found)
arguments)
1 = Switch faults masked
AAM * (message ok,
2 = Modem faults masked
but not permitted in
3 = All faults masked (audio never enabled)
current mode
Switch ID string
SID=
24 bytes,
Command or Query.
SID= (message ok)
SID?
SID=xxxxxxxx
ASCII
Sets or queries the user-defined Switch ID string, which is a
SID? (received ok,
xxxxxxxxxxxxx
fixed length of 24 characters.
but invalid arguments
xx (same format
Valid characters include:
found)
as command
Space ( ) * + - , . / 0-9 and A-Z.
arguments)