Comtech EF Data CRS-200 REDUNDANCY SWITCH User Manual

Page 37

Advertising
background image

CRS-200

COMTECH COMMUNICATIONS CORPORATION

CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL PAGE 35

INFO: SWITCH-ID SETUP

IF-SWITCH REMCONT MASK

SWITCH ID:

THIS IS A TEST MESSAGE

TM: 1 2 3 4 5 - 7 - 9 10

AUTO:OFF BKUP:05 REST:20

TRANSPONDER SWITCH IS

ABSENT

REM CNTL: ON RS485-4W

ADDRESS: 5000 19200 BAUD

INFO (Information)

The user is prompted to select SWITCH-ID, SETUP, IF-SWITCH, REMCONT or MASK
using the

LEFT/RIGHT keys, then ENTER. These screens display information on the

current configuration of the switch without risking inadvertent alterations.

(INFO)

SWITCH-ID

This displays the user-defined Switch ID string, which is entered via the

UTILITY, SWITCH-ID screen. To return to the previous menu, press
ENTER or CLEAR.

(INFO)

SETUP

The information on this screen reflects some of the settings configured

in the CONFIG, OPTIONS menu. Active traffic modems are listed on

the top line, with Auto mode and the two holdoff times listed on the

bottom.

(INFO)

IF-SWITCH

This screen shows whether a CRS-280 IF Transponder Switch is

connected to the CRS-200 1:N Redundancy Switch. When an IF switch

is present, the second line will indicate “PRESENT”, and any offline

modem (TM or RM) will not have its Transmit IF muted by the CRS-

200.

(INFO)

REMCONT (Remote Control Info)

This screen shows if the unit is in LOCAL or REMOTE mode, and gives

details of the electrical interface type selected, the unit’s address, and
the baud rate selected. Pressing

ENTER takes the user back to the

previous menu.