CRS-200
COMTECH COMMUNICATIONS CORPORATION
CRS-200 REDUNDANCY SWITCH - OPERATIONS MANUAL PAGE 34
EDIT LOCAL BUS BAUDRATE:
19200 BAUD (PRESS ENTER)
ELECT. INTERFACE: RS232
RS485-2W RS485-4W (ENT)
IN RS232 MODE THE BUS
ADDRESS IS FIXED AT 0000
EDIT SWITCH BUS ADDRESS:
3000 (PRESS ENTER)
(CONFIG, REM, BAUD)
If BAUD RATE is selected:
The user is prompted to edit the baud rate of the remote
control bus, connected locally to the M&C computer.
The value is changed using the
UP/DOWN arrow keys.
The user should then press
ENTER. Values of 300, 1200,
2400, 4800, 9600 and 19200 baud are possible. Note
that the asynchronous character format is FIXED at 8 data
bits, 1 stop bit, no parity (8-1-N).
(CONFIG, REM, INTFC)
If INTERFACE is selected:
The user is prompted to select RS232, RS485 (2-wire), or
RS485 (4-wire), using the
LEFT/RIGHT arrow keys, then
to press
ENTER. At this point the user will be further
prompted to enter the bus address. In RS232 mode the
bus address is fixed at 0, and the following screen will be
displayed:
(CONFIG, REM, INTFC, ADDR)
RS232 BUS ADDRESS
However, if either RS485 mode is selected, the
user will be further prompted:
(CONFIG, REM, INTFC, ADDR)
RS485 BUS ADDRESS:
The user is prompted to edit the RS485 bus
address of this unit. This is accomplished by
selecting the digit to be edited, using the
LEFT/RIGHT arrow keys. The value of the digit is
then changed using the
UP/DOWN arrow keys.
The user should then press
ENTER. The valid
addresses are 1000, 3000, 5000 and 7000 only,
as explained in the Remote section of this
manual.