Faults (j7), Tx if output (cp1), 3 faults (j7) – Comtech EF Data SNM-1001 User Manual

Page 28: 4 tx if output (cp1)

Advertising
background image

SNM-1001 Network Control Modem

Installation

Rev. 1

2–7

2.3.3 Faults

(J7)

The fault connector on the modem is used to provide FORM-C contact closures for the
purpose of fault reporting. There are three FORM-C summary fault contacts:

Modulator

Demodulator

Common equipment

To obtain a system summary fault, connect all FORM-C contacts in parallel.

The fault interface is provided on a 9-pin female D connector. Screw locks are provided
for mechanical security of the mating connector. The pinout of the connector is as
follows:

Pin #

Name

Function

1

NO

Common equipment is not faulted

2

COM

3

NC

Common equipment is faulted

4

NO

Modulator is not faulted

5

COM

6

NC

Modulator is faulted

7

NO

Demodulator is not faulted

8

COM

9

NC

Demodulator is faulted

Note: A connection between the common (COM) and normally open (NO) contacts
indicates no fault.

2.3.4

TX IF Output (CP1)

CP1 is the transmit IF connector. The output impedance is 75

. The output power level

is -5 to -30 dBm, in 0.1 dB steps.

In normal operation, the output will be a QPSK modulated result of the DATA I/O
connector, between 50 and 180 MHz.

Advertising