A.3.2 Demodulator

Set Demod
Frequency

Command:
Response:

Status:
Response:

<add/DF_nnn.nnnn'cr'
>add/DF_nnn.nnnn'cr''lf']

<add/DF_'cr'
>add/DF_nn.nnnn'cr''lf']

Where: nnn.nnnn = Frequency in MHz, 50.0000 to
180.0000, in 2.5 kHz steps.

Demod
Rate Preset
Assignment

Command:
Response

Status:
Response:

<add/ADRx_nnnn_mmm.mmm'cr'
>add/ADRx_nnnn_mmm.mmm'cr''lf']

<add/ADRx_'cr'
>add/ADRx_nnnn_mmm.mmm'cr''lf']

Where:

x = A, B, C, D, or V (Preset designator).
nnnn = 1/2, 3/4, 7/8, or BP12 (Decoder rate).
mmm.mmm = Data rate in kHz.

Notes:

1. When ADPCM Interface is selected, only 32.000 and

64.000 are allowed.

2. When the Async Interface is used. If the ASYNC

baud rate is higher than allowable for the new data
rate, the maximum baud rate will be selected
automatically.

Demod
Rate Preset
Selection

Command:
Response:

Status:

<add/SDRx_'cr'
>add/SDRx_'cr''lf']

See DR command.

Where: x = A, B, C, D, or V (Preset designator).

Demod
Rate
Variable
Assignment
& Selection

Command:
Response:

Status:

<add/SDRV_nnnn_mmm.mmm'cr'
>add/SDRV_nnnn_mmm.mmm'cr''lf']

See DR command.

Where:

nnnn = 1/2, 3/4, 7/8, or BP12 (Decoder rate).
mmm.mmm = Data rate in kHz.

Notes:

1. When ADPCM Interface is selected, only 32.000 and

64.000 are allowed.

2. When the Async Interface is used. If the ASYNC

baud rate is higher than allowable for the new data
rate, the maximum baud rate will be selected
automatically.

Descramble
Enable

Command:
Response:

Status:
Response:

<add/DE_xxx'cr'
>add/DE_xxx'cr''lf']

<add/DE_'cr'
>add/DE_xxx'cr''lf']

Where: xxx = ON or OFF.

Differential
Decoder
Enable

Command:
Response:

Status:
Response:

<add/DDEC_xxx'cr'
>add/DDEC_xxx'cr''lf']

<add/DDEC_'cr'
>add/DDEC_xxx'cr''lf']

Where: xxx = ON or OFF.

RF
Loopback

Command:
Response:

Status:
Response:

<add/RFL_xxx'cr'
>add/RFL_xxx'cr''lf']

<add/RFL_'cr'
>add/RFL_xxx'cr''lf']

Where: xxx = ON or OFF.

IF
Loopback

Command:
Response:

Status:
Response:

<add/IFL_xxx'cr'
>add/IFL_xxx'cr''lf']

<add/IFL_'cr'
>add/IFL_xxx'cr''lf']

Where: xxx = ON or OFF.