Demodulator faults, Transmit interface faults, Receive interface faults – Comtech EF Data SNM-1001 User Manual

Page 56: 3 transmit interface faults

Advertising
background image

SNM-1001 Network Control Modem

Maintenance

Rev. 1

5–11

5.2.2 Demodulator

Faults

5.2.2.1 Burst

Mode

Fault/Alarm

Possible Problem and Action

IF SYNTHESIZER

Demodulator IF synthesizer fault.

Indicates the demodulator IF synthesizer is faulted. This fault is a hardware
failure. Return the modem for repair.

MODULE

Demodulator module fault.

Typically indicates the demodulator will not program. This could indicate a
problem in the M&C or in the interface between the demodulator and M&C.
Return the modem for repair.

5.2.3

Transmit Interface Faults

Fault/Alarm

Possible Problem and Action

TX CLOCK ACT

Activity detector alarm of selected interface transmit clock.

Indicates the selected TX clock is not detected. Verify the signal at the
selected TX clock source. The interface will fall back to the internal clock
when this alarm is active.

5.2.4

Receive Interface Faults

5.2.4.1 Burst

Mode

This fault is not applicable when the modem is in the Burst mode.

Advertising