Remote Control Operation
SNM-1001 Network Control Modem
A–30
Rev. 1
Where 'pn' is the last parameter returned.
Parameter
Number
Parameter Name
(Command Reference)
Description
1
2
3
4
5
6
7
8
Local AUPC enable ON/OFF.
Nominal Power Value.
Minimum Power Value.
Maximum Power Value.
E
b
/N
0
Target Set Point.
Max. Tracking Rate.
Local Carrier Loss.
Remote Carrier Loss.
p1 = n, where 'n' is '0' (off) or '1' (on).
p2 = snn.n, where 'snn.n' Nominal Power Value in dBm.
p3 = snn.n, where 'snn.n' Minimum Power Value in dBm.
p4 = snn.n, where 'snn.n' Maximum Power Value in dBm.
p5 = n.n, where 'n.n' E
b
/N
0
Target Set Point in dB.
p6 = n.n, where 'n.n' is the Max. Tracking Rate in dB/Min.
p7 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).
p8 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2'
(MAXIMUM).