SNM-1001 Network Control Modem

Remote Control Operation

Rev. 1

A–29

Change
Status

Command:
Response:

<add/CS_'cr'
>add/CS_x'cr''lf']

Where: The 'x' character is defined as follows:

'@' = no change since last BCS_ and BCSF_ polls.

'A' = BCS_ response has changed since last BCS_
poll.

'B' = BCSF_ response has changed since last BCSF_
poll.

'C' = Both responses have changed since last BCS_
and BCSF_ polls.

This command indicates that a change has or has not
occurred on either the BCS_ or the BCSF_ response since
the last BCS_ or BCSF_ poll.

Equipment
Type

Command:
Response:

<add/ET_'cr'
>add/ET_tttttttt_xxx.yyy.zzz'cr''lf']

Where:

tttttttt = Equipment type.
xxx.yyy.zzz = Software version.

This command returns the equipment type and the
software version of the addressed device.

Monitor &
Control
Firmware
Information

Command:
Response:

<add/MCFI_'cr'
>add/MCFI_'cr'
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']

Where:

xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).

nnnnnn = Firmware number (0 to 999999).

dd = Firmware dash number (0 to 99).

r = Firmware revision (-, or A to Z).

DATA ROM
Firmware
Information

Command:
Response:

<add/DFI_'cr'
>add/DFI_'cr'
DSP_FW/nnnnnn-ddr'cr'
DSP_mm/dd/yy'cr'
FPGA_FW/nnnnnn-ddr'cr'
FPGA_mm/dd/yy'cr''lf']

Where:

nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).

Interface
Type

Command:
Response:

<add/IT_'cr'
>add/IT_ttttt'cr''lf']

Where: ttttt = RS422, V.35, RS232, ADPCM, or ASYNC.

This command returns the Interface equipment type.

Bulk Consol
Status
AUPC

Command:
Response:

<add/BCSA_'cr'
>add/BCSA_p1,p2,p3, . . . pn'cr''lf']