Comtech EF Data UT-4500 Series User Manual

Page 27

Advertising
background image

UT4500 Series Up Converter

MN/UT4500.IOM

Introduction

Revision 2

9

Characteristic

Specification

Phase Noise

100 Hz

1 KHz

10 KHz

100 KHz

1 MHz

Limit (dBc/Hz)
-69

-79

-89

-99

-109

Typical (dBc/Hz)

-72

-82

-92

-102

-112

Remote Control (Rear Panel)

Comm Port EIA-485 or EIA-232

Indicators (Front Panel)
Power

On

Mute
Remote
Reference
Stored

Fault

Fault


Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED

Test Points (Front Panel)
RF

Sample

IF

Sample

Optional L.O. Sample


SMA, -20 dBc Nominal
BNC, -20 dBc Nominal

Power
Voltage
Frequency
Dissipation


90 to 250 Vac Autoranging, optional –48 Vdc
47 to 63 Hz
60 Watts

Environmental
Temperature
Altitude
Humidity


0 to 50° C (32 to 122° F)
10,000 Feet MSL
0 to 95 % Relative

Physical
Width
Height
Depth
Weight


19 Inches

(48.30 cm)

1.75 Inches

(4.45 cm)

22 Inches

(55.90 cm)

15 Pounds

(7.00 kg)

MTBF

49,740 hrs.

(calculated)

>100,000 hrs. (field experience)

Summary Alarm
Relay

Closure


Form C

Advertising