Synthesizer faults, Converter over temperature fault, Stored faults – Comtech EF Data UT-4500 Series User Manual

Page 56: Total stored faults, Clear all stored faults, Display stored fault

Advertising
background image

UT4500 Series Up Converter

MN/UT4500.IOM

System Operation

Revision 2

38

3.3.5.3 S

YNTHESIZER

F

AULTS

Displays the synthesizer faults:

Sum Loop Detect.

Coarse Loop Detect.

Fine Loop Detect.

3.3.5.4 C

ONVERTER

O

VER

T

EMPERATURE

F

AULT

Displays a converter temperature fault condition.

3.3.6 S

TORED

F

AULTS

The converter displays a total of one hundred (100) faults which are date and time
stamped and stored in memory as they occur. The stored faults remain in memory until a
clear command is entered. When the number of faults reaches 100, the 100

th

fault will

display ER.

3.3.6.1 T

OTAL

S

TORED

F

AULTS

Displays the total number of faults stored. The most recent fault stored is displayed on
the LCD display.

3.3.6.2 C

LEAR

A

LL

S

TORED

F

AULTS

Input command to clear all faults. The command is "YES" or "NO' which is displayed on
the LCD display.

3.3.6.3 D

ISPLAY

S

TORED

F

AULT

The local operator can sequence through the stored faults starting with the most recent
fault. The fault number, time, description and date is displayed on the LCD display.

Advertising