UT4500 Series Up Converter

MN/UT4500.IOM

Remote Control

Revision 2

77

5.7 E

RROR

P

ROCESSING

5.7.1 G

ENERAL

E

RRORS

The following Error Responses may be generated by any command instead of a
confirmation:

>DEV?COM CU CMD UNRECOGNIZED'cr''lf']
>DEV?COM IP INVALID PARAM'cr''lf']
>DEV?COM PE PARITY ERROR'cr''lf']

5.7.2 C

ONFIGURATION

E

RRORS

The following Error Responses may be generated by configuration commands:

>DEV?COM LO DEVICE IN LOCAL MODE'cr''lf']

5.7.3 M

ODE

E

RRORS

The following Error Responses may be generated by Mode selection:

>DEV?COM AE ONLY VALID WHEN BACKUP'cr''lf']
>DEV?COM OE OFFLINE NOT AVAILABLE'cr''lf']
>DEV?COM CN COMMAND NOT AVAILABLE'cr''lf']

5.7.4 T

IME

-O

UTS

A time-out should be assumed if there is no response in 500 milliseconds. The station
monitor and control computer should try at least three times.