Maintenance status, Utility status, Alarm status – Comtech EF Data UT-4500 Series User Manual
Page 90
![background image](/files/778940/content/doc090.png)
UT4500 Series Up Converter
MN/UT4500.IOM
Remote Control
Revision 2
72
5.6.4.2 M
AINTENANCE
S
TATUS
Command
Details
Maintenance Status:
<DEV/RMS_'cr'
Confirmation: >DEV/RMS_'cr'
P15_xx.x'cr'
15 Vdc Supply
P14_xx.x'cr'
14 Vdc Supply
VCC_x.x'cr'
VCC
Supply
5VD_x.x'cr'
Display 5 Vdc
TEM_xx'cr'
Temperature
IFL_xx.x'cr'
IFLO
Tuning
SUM_xx.x'cr'
Sum Loop Tuning
COR_xx.x'cr'
Coarse Loop Tune
FIN_xx.x'cr''lf'] Fine Loop Tuning.
5.6.4.3 U
TILITY
S
TATUS
Command
Details
Utility Status:
<DEV/RUS_'cr'
Confirmation: >DEV/RUS_'cr'
COMM_aaaaaa'cr'
RS-232
or
RS-485
ADD_xxx'cr'
Address (001 to 255)
BR_nnnn'cr'
Baud Rate (1200, 2400, 4800, 9600,
19K2,
or
38K4)
FMT_x-y-z’cr’
Data Format x=data, y=parity, z=stop
bit
(8-N-1,
7-E-2,
7-O-2)
REF_xxx'cr'
Osc. Adjust (000 to 255)
SLP_x.x'cr'
Slope Adjust (0.0 to 1.0)
CON_xx'cr'
LCD Contrast (0 to 30)
LCD_xx'cr''lf']
LCD Brightness (0 to 30).
5.6.4.4 A
LARM
S
TATUS
Command
Details
Alarm Status:
<DEV/RAS_'cr'
Confirmation: >DEV/RAS_'cr'
P15_xx'cr'
15 Vdc Fault
P14_xx'cr'
14 Vdc Fault
VCC_xx'cr'
VCC
Fault
5VD_xx'cr' 5VD
Fault
TEM_xx'cr'
Temperature
Fault
IFL_xx'cr'
IFLO Lock Fault
SUM_xx'cr'
Sum Lock Fault
COR_xx'cr' Coarse
Lock
Fault
FIN_xx'cr'
Fine lock Fault
HSB_xx’cr’
High Speed Bus Fault
*REF_xx'cr''lf'] Ref. Lock Fault
xx = OK or FT
Note: REF_xx is only returned if an external reference is present.