background image

UT4500 Series Up Converter

MN/UT4500.IOM

Remote Control

Revision 2

49

4.4 R

EDUNDANT

S

YSTEM

C

ONFIGURATION

4.4.1 I

NITIAL

C

ONFIGURATION

Redundant system configuration is controlled from the converter’s front panel
configuration menu. Each online unit is assigned a redundancy configuration address.
This address is dependent on the location of the online converter with reference to the
backup. The unit closest to the backup must be converter # 1. The next unit down must
be converter # 2. Figure 29 shows the appropriate entries for a 1:3 system

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-BU---1:03--

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-01---------

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-02---------

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-03---------

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

Figure 29. 1:3 Front Panel Displays

Configure the online units first, and then configure the backup unit. Redundant polling
starts when the backup is configured. If this polling starts before the online units are
configured, a high-speed bus fault will result. This fault should clear when configuration
is completed. At this point, control of the redundant system is performed from the backup
converter.