UT4500 Series Up Converter

MN/UT4500.IOM

Remote Control

Revision 2

71

5.6.3.3 B

ACKUP

M

ODE

This command allows the user to force a backup condition for maintenance and test
purposes. This command must be sent to the converter designated as the backup
converter (i.e., “BU”). When activated this command forces the backup converter to
assume the state of the specified chain converter and forces the chain converter offline.

Command

Details

Initiate a Backup:

<DEV/FBU_xx_y'cr'

Confirmation: >DEV/FBU_xx_y'cr''lf']

Where: xx = 01 to 12, converter number

y = ‘F’ to force a backup ‘N’ to remove a backup

Retrieve Backup
Status:

<DEV/FBU_'cr'

Confirmation: >DEV/FBU_xx_zzzzz'cr''lf']

Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter

number is not displayed.

zzzzz = ‘NONE’ if no backup active

= ‘ACTIVE’ if an automatic backup has occurred

= ‘FORCED’ if a forced backup is active

5.6.4 S

TATUS

C

OMMANDS

Status commands retrieve configuration, maintenance and alarm status in summary form.

5.6.4.1 C

ONFIGURATION

S

TATUS

Command

Details

Configuration Status: <DEV/RCS_'cr'

Confirmation: >DEV/RCS_'cr'

FRE_xxxxx.xxx'cr'

Frequency

ATT_yy.yy'cr'

Attenuator

TX_nnn'cr'

Transmitter

-

ON/OFF/COLD

ONL_nnn'cr'

Online

-

ON/OFF

RED_xx_yy_z'cr' See

Note

CLD_nnn'cr'

Cold Start - ON/OFF

AFR_nnn'cr'

Auto

Flt

Recovery-ON/OFF

EXT_xxx'cr''lf']

Ext. Ref. - YES/NO

Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as

backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain
(i.e. 01 to 12), else if Redundancy ON and converter selected as a chain unit xx is the
converter number (01 to 12), and z = A if Auto Mode or M if Manual Mode.



Advertising