Message structure, Start character, Device address – Comtech EF Data UT-4500 Series User Manual

Page 79: Command, Confirmation response

Advertising
background image

UT4500 Series Up Converter

MN/UT4500.IOM

Remote Control

Revision 2

61

5.5 M

ESSAGE

S

TRUCTURE

The structure of either a Command , Response or Error Message is as follows:

Start Character.

Device Address.

Command or Response.

End of Message String.

5.5.1 S

TART

C

HARACTER

The Start Character begins each message:

Example:

< Start of a user Command.

> Start of a converter response.

5.5.2 D

EVICE

A

DDRESS

The Device Address consists of a Physical Address or a Physical Address and an
appended Virtual Address. For this document DEV is used for the generic case
examples.

Example: <3V12

5.5.3 C

OMMAND

A Command is a variable length character string beginning with a / and containing either
an instruction or an instruction and data for a converter to act upon. If data is passed by
command it is appended to the instruction by an underscore( _ ). If data is retrieved by
command underscore follows the instruction flagging the converter to supply data in a
response. In this document /COM is used for the generic case examples.
Example:

<DEV/COM_xxx'cr' Sends data to a converter.

Example:

<DEV/COM_'cr'

Requests information from a converter.

5.5.4 C

ONFIRMATION

R

ESPONSE

A confirmation will change the start character, and echo the Device Address and
Command. Any requested data will be appended to the Command.
Example: >DEV/COM_xxx'cr''lf']