Configuration functions menu, Frequency operating mode, External reference – Comtech EF Data UT-4500 Series User Manual

Page 54: Entry mode/cold start, Fault recovery, Redundancy mode, Pre-select function menu, Display pre-select

Advertising
background image

UT4500 Series Up Converter

MN/UT4500.IOM

System Operation

Revision 2

36

3.3.2 C

ONFIGURATION

F

UNCTIONS

M

ENU

The Configuration Functions are as follows:

3.3.2.1 F

REQUENCY

O

PERATING

M

ODE

Frequency (FREQ):

Displays the current converter frequency in MHz, and allows the selection of a
new frequency channel between RF

Low

to RF

High

MHz (e.g.; 14000.000 to

14500.000 MHz for Model UT-4514) in 125 KHz steps through keypad inputs.

Attenuation (ATTN):

Input and displays the converter attenuation setting which is selected between
0.00 to 25.00 in 0.25 dB steps. The default setting is 10.00 dB.

Tx:

The converter is ON or OFF. The default mode is OFF.

3.3.2.2 E

XTERNAL

R

EFERENCE

External Reference:

The External Reference is displayed only when the 5 or 10 MHz external
reference input to the converter is present.

3.3.2.3 E

NTRY

M

ODE

/COLD S

TART

The entry mode is Local or Remote. The default is Remote.
COLD Start:

The COLD Start Mode, if enabled, mutes the converter output signal for a pre-
determined time, 15 minutes, after power is applied to the converter to ensure that
the reference oscillator is stable. The default mode is Disabled. This function is
disabled in redundant systems.

3.3.2.4 F

AULT

R

ECOVERY

Fault Recovery:

Fault Recovery is Manual or Auto. The default is Auto.

3.3.2.5 R

EDUNDANCY

M

ODE

Refer to Chapter 4, Redundant System Operation.

3.3.3 P

RE

-

SELECT

F

UNCTION

M

ENU

3.3.3.1 D

ISPLAY

P

RE

-S

ELECT

Displays the frequency and attenuation pre-selects for the converter. 1 to 32 frequencies
can be pre-selected. If no frequencies have been pre-selected, the LCD display will
indicate "NONE".

Advertising