Packed maintenance status, Packed utility status – Comtech EF Data UT-4500 Series User Manual

Page 92

Advertising
background image

UT4500 Series Up Converter

MN/UT4500.IOM

Remote Control

Revision 2

74

5.6.4.8 P

ACKED

M

AINTENANCE

S

TATUS

Packed Maintenance Status: <DEV/PACRMS_'cr'
Confirmation:

>DEV/PACRMS_aabbccddeeeffgghhii'cr''lf']

where:

aa = V15 scaled 123mV per count (0x00 - 0xFF)

bb = V14 scaled 123mV per count (0x00 - 0xFF)

bc = VCC scaled 39mV per count (0x00 - 0xFF)

dd = V5D scaled 39mV per count (0x00 - 0xFF)

eee = signed Temperature in degrees C (-10 to +60)

ff = IFLO tune scaled 67mV per count (0x00 - 0xFF)

gg = SUM tune scaled 54mV per count (0x00 - 0xFF)

hh = COARSE tune scaled 78mV per count(0x00 - 0xFF)

ii = FINE tune scaled 89mV per count (0x00 - 0xFF)

5.6.4.9 P

ACKED

U

TILITY

S

TATUS

Packed Utility Status:

<DEV/PACRUS_'cr'

Confirmation:

>DEV/PACRUS_abbcdeeffghhii'cr''lf']

where:

a = 0=EIA-232, 1=EIA-485

bb = Address in hex (01 to FF)

c = 0 if Baud Rate 38400

= 1 if Baud rate 19200

= 2 if Baud rate 9600

= 3 if Baud rate 4800

= 4 if Baud rate 2400

= 5 if Baud rate 1200

d = 0 if Data Format 8-N-1

= 1 if Data Format 7-E-2

= 2 if Data Format 7-O-2

ee = Osc. Adjust in hex (00 to FF)

ff = Slope Adjust times by 10 (00 to 10)

g = Always 0, unused

hh = LCD Contrast (0 to 30)

ii = LCD Brightness (0 to 30)