Digital Alert Systems: DASDEC User Manual

151

5. At the bottom of the page, you can choose from some further options that will regulate your RWT. The first option

Include qualified forwarded alerts for blocking creation of Random Weekly Tests, instead of just qualified
originated alerts
could be important. This option, when enabled, does not schedule a weekly test if your station
has forwarded a weekly test that was decoded from another station. You can choose what you want to do with
this option. If you have set up your decoder to NOT forward weekly and monthly tests automatically, then do not
enable this option. Conversely, if you have set up your decoder settings to forward weekly and monthly tests
automatically, you might want to enable this option.

Here is a screenshot of a configured One-button and Automatic RWT generation page:

Now that you have set that all up, you can either wait for your DASDEC to pick a time to forward an RWT (within
your specified time) or, you can go to

Encoder > One-Button Alert

and press on the big button to forward the

RWT over your broadcast when you want to. I would recommend letting your DASDEC do the planning for you,
even though pressing that big button is tempting.