 38   

 

Digital Alert Systems: DASDEC User Manual

   

Setup > Email > Decoder Email

Email upon Alert Decoding: Check the box to disable or enable Email on Alert Decoding. If enabled, enter
the Email address in the Email To: field.

Email upon Alert Forwarding: Check the box to disable or enable Email upon Alert Forwarding. If enabled,
enter the Email address in the Email To: field.

Click Accept Changes.

4.5.4 Encoder

Email

To setup the outgoing email for the DASDEC II encoder events, select Setup Email > Encoder Email.
Email can be sent upon alert origination. Follow screen instructions or the same method described above for
Decoder Email. Click Accept Changes for any changes to be effective.

Setup > Email > Encoder Email

4.6 Setup

>

Audio

Audio is at the heart of an EAS system. From the factory, a DASDEC is configured ready for average field situations. The
EAS in your specific area could require some special tuning. At minimum, you will need to use the Setup Audio pages to
tune the Radio stations used for EAS monitoring. You will also likely need to adjust the decoder input levels for the
selected stations, since every station will vary in its signal strength. The audio output levels may also need some
adjustment to fit with your broadcast parameters.