Set FIPS locations for One-Button Weekly Test: Select one or more FIPS location(s) from the available
FIPS codes selection box. If a FIPS code is not available on the list, follow the

FIPS list can be configured

text link to the Setup Encoder General Options web page to add the FIPS code into the available FIPS list.
See Chapter 4.9.1 General: Main Encoder Configuration.
After selecting the code(s), click

.

The FIPS location(s) added will appear in the list of Current FIPS locations for One-Button Weekly Test
(lower right side of section).

Optional Pre-Alert Audio Announcement
Use the pull-down menu to select a Pre-Alert Audio Announcement to be played before the Weekly test EAS
header audio.

Optional Post-Alert Audio Announcement
Same as pre-alert, except played after the EAS EOM audio. When an audio file is selected in either of these
selection menus, the Duration of the file in minutes and seconds is displayed, as well as the file Sample
Rate
. A text link Goto to > Setup Audio Output Levels is provided to allow quick access to the interface for
listening to and uploading audio files.

Set One-Button Weekly Test Duration
This interface sets the EAS duration for the Weekly Test. The number of hours can be typed from 0-99.
Select number of minutes from the pull-down menu.

Current FIPS locations for One-Button Weekly Test
For each FIPS location code you can use the pull-down menu on the left side of the FIPS to select a
subdivision quadrant for the FIPS location. Usually this can be left at the All setting. A FIPS location can be
deleted from the list using the

button.


Include qualified forwarded alerts for blocking creation of Random Weekly Tests, instead of just
qualified originated alerts

Random Weekly Tests (RWT) will be scheduled without regard to Weekly, Monthly, or Emergency alert
forwarding. Check to enable.

Automatically Manage random Weekly Test removal upon airing of qualified alerts
Random Weekly Tests (RWT) remains scheduled regardless of other alerts that air. Check to enable.

Front Panel Button Weekly Test

This checkbox controls whether the DASDEC II Front Panel button is enabled or disabled for issuing a
Weekly Test alert. Defaults to Enabled. Uncheck to Disable.

4.9.3 Other

The Setup Encoder > Other sub-page provides a set of active links into the following pages:

Encoder Audio Configuration
Goto > Setup Encoder Audio Levels
Goto > Setup Audio Output Levels and Tests

Encoder Video Configuration
Goto > Setup Encoder Video & Character Generator Output

Encoder Network Send Configuration
Goto > Setup Network Alert Configuration

Encoder Email Configuration
Goto > Setup Encoder Email Output
Goto > Setup Email Server

Advertising