Digital Alert Systems DASDEC-II MANUAL User Manual

Page 63

Advertising
background image

Digital Alert Systems: DASDEC User Manual

57

Crawl Font – Defaults to one.
Set from 1 to 4.

Char Color – Defaults to white.

Set Color Background by EAS Severity? – Defaults to disabled. When enabled, the text color is
determined based on a color selection set for the EAS severity category.

Iterations – Defaults to one. Crawl is done once.
Set from 1 to 100.

Speed – Defaults to Fast.
Choose from three speeds: Fast, Medium or Slow.

VDS Mode – Defaults to VDS840.
Select from VDS840, VDS830, Starmu/Star8 and Sage Emulation. The Sage Emulation mode has an
optional page of text that can be programmed.

Vertical position – Defaults to video 20.
Set from 20 (topmost) to 208 (bottommost).

Serial Port Baud Rate – Defaults to 9600 Select 9600 or 19200 baud depending on the remote CODI
device requirements.

Serial Port Bit Config Rate – Set data bits and stop bits depending on the remote VDS device
requirements.

Delay crawl – Defaults to disabled. When enabled, the crawl is delayed until after the EAS audio
header and attention two-tone signal is played.

Repeat Alert Video Display – Defaults to Do Not Repeat.
Select from a set of options for repeating the data write to the remote device after a pause period set
from the Set Alert Video Repetition Period field. The repeat period has to be at least 2 minutes.


5. Sage Generic CG Attribute Settings

Serial Port Baud Rate – Defaults to 9600. Select 9600 or 19200 baud depending on the remote device
requirements.

Serial Port Flow Control
– Select Hardware or Software or None depending upon the hardware
support on the remote device.

Throttle down serial port write speed –
Defaults to disabled.
When Enabled, data is written with pauses between 128 byte blocks. This can be helpful when sending
this to devices that cannot do flow control.

Iterations
– Defaults to one. Crawl is done once.
Set from 1 to 5.

Repeat Alert Video Display
– Defaults to Do Not Repeat.
Select from a set of options for repeating the data write to the remote device after a pause period set
from the Set Alert Video Repetition Period field. The repeat period has to be at least 2 minutes.


6. Sage News Room Attribute Settings

Immediate display upon matching decoded alert – Defaults to disabled. When enabled, data for
matching FIPS and EAS filtered alerts is sent to the remote device using the Sage News Room
protocol.

Serial Port Baud Rate – Defaults to 9600. Select 9600 or 19200 baud depending on the remote device