Figure 3-2: Alloy cross-reference chart
Flowserve
Material Code
Designation
Durco Legacy
Codes
ACI
Designation
Equivalent Wrought
Designation
ASTM
Specifications
Material
Group No.
E3020
Ductile iron
DCI
None
None
A395, Gr. 60-40-18
1.0
E3033
High chrome iron
CR28
None
None
A532 class 3
Cr
E4027
High chrome iron
CR29
None
None
None
Cr
E4028
High chrome iron
CR35
None
None
None
Cr
C3009
Carbon steel
DS
None
Carbon steel
A216 Gr. WCB
1.1
C3062
Durco CF8
D2
CF8
304
A744, Gr. CF8
2.1
C3069
Durco CF3
D2L
CF3
304L
A744, Gr. CF3
2.1
C3063
Durco CF8M
D4
CF8M
316
A744, Gr. CF8M
2.2
C3067
Durco CF3M
D4L
CF3M
316L
A744, Gr. CF3M
2.2
C3107 Durcomet
100
CD4M CD4MCuN
Ferralium
®
A995, Gr. CD4MCuN
2.8
C4028
Durimet 20
D20
CN7M
Alloy 20
A744, Gr. CN7M
3.17
C4029 Durcomet
5 DV
None None
None
2.2
K3005 Durco
CY40
DINC
CY40 Inconel
® 600
A494, Gr. CY40
3.5
K3007 Durco
M35 DMM
M351 Monel
® 400
A494, Gr. M35-1
3.4
K3008
Nickel
DNI
CZ100
Nickel 200
A494, Gr. CZ100
3.2
K4007 Chlorimet
2 DC2
N7M Hastelloy
® B
A494, Gr. N7M
3.7
K4008 Chlorimet
3 DC3
CW6M
Hastelloy
® C
A494, Gr. CW6M
3.8
E3041
Duriron
®
D
None
None
A518, Gr. 1
No load
E3042
Durichlor 51
®
D51
None
None
A518, Gr. 2
No load
E4035
Superchlor
®
SD51
None
None
A518, Gr. 2
No load
D4036 Durco
DC8 DC8
None None
None
-
H3004 Titanium Ti
None Titanium
B367, Gr. C3
Ti
H3005 Titanium-Pd
TiP
None Titanium-Pd
B367, Gr. C8A
Ti
H3007 Zirconium Zr
None Zirconium
B752, Gr. 702C
Ti
® Duriron, Durichlor 51 and Superchlor are registered trademarks of Flowserve Corporation.
® Ferralium is a registered trademark of Langley Alloys.
® Hastelloy is a registered trademark of Haynes International, Inc.
® Inconel and Monel are registered trademarks of International Nickel Co. Inc.
3.4.2 Pressure-temperature ratings
The maximum allowable discharge pressure is
6.9 bar (100 psi) from -29 to 176˚C (-20 to 350˚F).
3.4.3 Suction pressure limits
Suction pressure is limited only by the pressure
temperature ratings of the pump. Specific gravity is
limited to 2.0.
3.4.4 Minimum continuous flow
The minimum continuous flow (MCF) is based on a
percentage of the best efficiency point (BEP). Figure
3-3 identifies the MCF.
Figure 3-3: Minimum continuous flow
MCF % of BEP
Pump size
1750/1450
r/min
1180/960
r/min
2K4x3H-13 20% 10%
All other sizes
10%
10%
4 INSTALLATION
High Silicon Iron components
If any of the components of the pump
have been made of High Silicon Iron, the following
precautionary measures should be followed:
• Use hand wrenches rather than impact wrenches
• This equipment should not be subjected to
sudden changes in temperature or pressure
• Avoid striking this equipment with any sharp blows
High Silicon Iron components
Avoid any repair or fabrication welds
on High Silicon Iron components.
4.1 Location
The pump should be located to allow room for
access, ventilation, maintenance, and inspection with
ample headroom for lifting and should be as close as
practicable to the supply of liquid to be pumped.
Refer to the general arrangement drawing for the
pump set.
Page 12 of 48