PATHFINDER WITH EAGLE CONTROLLER SETUP

Confi guring the Pathfi nder

1.)

The Pathfi nder is confi gured with an IP address compatible with the Eagle controller. The address
is 192.168.0.243. The IP port address is also confi gured to Port 23. No other confi guration is
necessary. To check and/or change the address the IP address can be accessed via the front panel
by getting into the setup menu (pressing the up and down buttons simultaneously), then selecting
SYSTEM SETUP, TCP/IP - DUET SETUP.

Setting Up the Eagle Controller

2.)

There is a distinct order for confi guring Eagle Controller and Pathfi nder. Following this order makes
the process simpler, and prevents omission of key steps. The order of setup is as follows:

System Reset

A.)

Destination Setup

B.)

Router Setup

C.)

Output Patch Setup

D.)

Input Patch Setup

E.)

Output Setup

F.)

Input Setup

G.)

Save Setups

H.)

The Eagle 200 Controller has two rotary encoders (knobs) that are used for navigation and option
selection. Use the top rotary encoder to scroll up or down lines. Then use the bottom rotary encoder
to change the option. When this document says scroll down, the top rotary encoder to scroll down.
When this document says select an option use the bottom rotary encoder.

NOTE: Prior to setting up the Eagle Controller, set any Eagle 200 Switcher/ scalers that are
controlled in the system to "REMOTE CONTROL ON" under the "REMOTE CONTROL" menu
section in each of their setup menus as shown below:

Select "REMOTE CONTROL" from the main EAGLE 200 switcher/scaler setup screen