Table 8. Transmission Direction Hold Time on 69443-xxx PCBA

SW2-5 SW2-6 Transmission

Direction

Hold

Time

Open (up)*

Open (up)*

1280 milliseconds

Closed (down)

Open (up)

640 milliseconds

Open (up)

Closed (down)

160 milliseconds

Closed (down)

Closed (down)

40 milliseconds

N

OTE

: Changes to this parameter take effect without cycling power.

Table 9. Peak Voltage Level Detection Threshold on 69443-xxx PCBA

SW2-7

Peak Voltage Level Detection Threshold

Open (up)*

-12 dB relative to nominal

Closed (down)

-24 dB relative to nominal

N

OTE

: Changes to this parameter take effect without cycling power.

Table 10. Echo Cancellation Power-On Delay Setting on 69443-xxx PCBA

SW6-1

Echo Cancellation Power-On Delay

Open* One

minute

Closed No

delay

N

OTES

: 1. Changes to this parameter take effect when cycling power.

2.

*Indicates

default

position.