f:\standard ioms - current release\42004 instr. manuals\42004-701l2f.doc
04/09

Series Connection of Page/Party

®

System

Figure 12. Series Connection of Page/Party

®

System

Table 38. Series Connection of Page/Party

®

System Table

Parameter Switch

Configuration

Description

T1 Line
Length

SW2

Determined by installation distance between each pair of line extenders:
• A to B
• C to D

T1/E1 Clock
Source

SW3-1

SW3-2

• Units A and C are the master clock sources: SW3-1 (open) SW3-2 (open)
• Unit B uses the T1/E1 clock from Unit A: SW3-1 (closed) SW3-2

(closed)

• Unit D uses the T1/E1 clock from Unit C: SW3-1 (closed) SW3-2

(closed)

LVDS Clock
Source

SW3-3

SW3-4

LVDS clock is used between units B and C:
• Unit B - “in” disabled, “out” enabled: SW3-3 (open) SW3-4 (closed)
• Unit C - “in” enabled, “out” disabled: SW3-3 (closed) SW3-4 (open)

Mute Analog
Lines

SW6-4

Unit C is muted since no Page/Party

®

cable is connected:

SW6-4 (closed).