Page Line Audio Detected Contact Output

The Model LE200 provides a contact closure output that activates whenever audio is detected on the page
line. The contact can be set to close on audio detection of either the local page line, the remote page line
audio, or both. The contact remains active for one second after the audio is no longer detected. DIP
switch SW5 enables or disables the local and remote page line audio detection contact output. Refer to
Table 12 and Table 13 below for switch setting.

Table 12. Local Page Line Audio Detect Contact on 69443-xxx PCBA

SW5-6

Page Line Audio Detect Contact Uses Local Page Audio

Open*

Local page line audio activates the contact.

Closed

Local page line audio does not activate the contact.

N

OTES

: 1. Changes to this parameter take effect without cycling power.

2.

*Indicates

default

position.

Table 13. Remote Page Line Audio Detect Contact on 69443-xxx PCBA

SW5-7

Page Line Audio Detect Contact Uses Remote Page Audio

Open*

Remote page line audio activates the contact.

Closed

Remote page line audio does not activate the contact.