GAI-Tronics LE200, LE200-FSR, LE200-FLR Page/Party Line Extenders User Manual

Page 24

Advertising
background image

Pub. 42004-701L2F

M

ODEL

LE200

S

ERIES

W

ALL

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDERS

P

AGE

22 of 50

f:\standard ioms - current release\42004 instr. manuals\42004-701l2f.doc
04/09

Table 24. Line Connection Relay Enable SW4 DIP Switch Setting on 69443-xxx PCBA

SW4 Switch Setting

Field Wiring Connection

SW4-1

Open

Party line #5 is not connected to the field wiring.

Closed*

Party line #5 is connected to the field wiring.

SW4-2

Open

Party line #4 is not connected to the field wiring.

Closed*

Party line #4 is connected to the field wiring.

SW4-3

Open

Party line #3 is not connected to the field wiring.

Closed*

Party line #3 is connected to the field wiring.

SW4-4

Open

Party line #2 is not connected to the field wiring.

Closed*

Party line #2 is connected to the field wiring.

SW4-5

Open

Party line #1 is not connected to the field wiring.

Closed*

Party line #1 is connected to the field wiring.

SW4-6

Open

The page line is not connected to the field wiring.

Closed*

The page line is connected to the field wiring.

SW4-7

Open

The monitor output is not connected to the field wiring.

Closed*

The monitor output is connected to the field wiring.

SW4-8 Open Not

used.

Closed*

Not

used.

N

OTES

: 1. Changes to this parameter take effect without cycling power.

2.

*Indicates

default

position.

Advertising
This manual is related to the following products: