5 – jumpers & switch settings, Site controller comm cpu printed circuit board, Jumpers, k3 to k12 – Gasboy Site Controller III Start-Up User Manual
Page 47: Jumpers & switch settings, Figure 5-1: sc iii comm cpu board, Important
Advertising

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005
Page 35
Jumpers & Switch Settings
5 – Jumpers & Switch Settings
This section covers the jumper and switch settings for the various components of your Site
Controller III system.
Site Controller COMM CPU Printed Circuit Board
Figure 5-1: SC III Comm CPU Board
Jumpers, K3 to K12
Jumper
Function
Setting
K3
AC power fail sense
2 - 3 to enable
1 - 2 to disable
K4
AC watchdog timer
1 - 2 to enable
K5
SC - Comm CPU (testing only)
1 - 2 to reset
K6
RS-485 loop 1, 2 to 4 wire
2 - 3 for 4 wire
1 - 2 for 2 wire
K7
RS-485 loop 2, 2 to 4 wire
2 - 3 for 4 wire
1 - 2 for 2 wire
It is important that the jumpers and switch settings be set properly to ensure correct
operation.