Figure 12-9: example of re pu command with prompt – Gasboy Site Controller III Start-Up User Manual

Page 98

Advertising
background image

Start-up Commands

Page 86

MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005

3

Type LO IN;C to load inventory amounts and reorder levels for fuel products (

Figure 12-8

).

Note: LO IN automatically enables inventory tracking. For more information on inventory

tracking, see the Site Manager’s Manual.

Figure 12-8: Example of LO IN;C Command with Prompts

4

Type RE PU to reset the pumps to zero (

Figure 12-9

).

If you wish to set the quantity and dollar totalizers maintained by the Site Controller to the
same settings as the mechanical totalizers on the pump, do a LO PU;C command (

Figure 12-

10

).

Note: You may load up to five hoses per pump. When you enter the last hose for a particular

pump, press RETURN at the next hose number prompt to get the next Pump Number
prompt.

Figure 12-9: Example of RE PU Command with Prompt

Figure 12-10: Example of LO PU;C Command with Prompts

R* LO IN;C <RETURN>

Product? 1 <RETURN>

Quantity? 400 <RETURN>

Reorder level? 100 <RETURN>

R*

R* RE PU <RETURN>

Verify (Y/N)? Y <RETURN>

R*

R* LO PU;C <RETURN>

Pump number? 1 <RETURN>

Hose number? 1 <RETURN>

Quantity? 5624.8 <RETURN>

$amount? 3217.95 <RETURN>

Hose number? <RETURN>

Pump number? 2 <RETURN>

Hose number? 2 <RETURN>

Quantity? 2345.9 <RETURN>

$amount? 6789.10 <RETURN>

Hose number? <RETURN>

Pump number? <RETURN>

R*

Advertising