Figure 12-9: example of re pu command with prompt – Gasboy Site Controller III Start-Up User Manual
Page 98

Start-up Commands
Page 86
MDE-4375 CFN Series Site Controller III Start-Up Manual · June 2005
3
Type LO IN;C to load inventory amounts and reorder levels for fuel products (
).
Note: LO IN automatically enables inventory tracking. For more information on inventory
tracking, see the Site Manager’s Manual.
Figure 12-8: Example of LO IN;C Command with Prompts
4
Type RE PU to reset the pumps to zero (
).
If you wish to set the quantity and dollar totalizers maintained by the Site Controller to the
same settings as the mechanical totalizers on the pump, do a LO PU;C command (
Note: You may load up to five hoses per pump. When you enter the last hose for a particular
pump, press RETURN at the next hose number prompt to get the next Pump Number
prompt.
Figure 12-9: Example of RE PU Command with Prompt
Figure 12-10: Example of LO PU;C Command with Prompts
R* LO IN;C <RETURN>
Product? 1 <RETURN>
Quantity? 400 <RETURN>
Reorder level? 100 <RETURN>
R*
R* RE PU <RETURN>
Verify (Y/N)? Y <RETURN>
R*
R* LO PU;C <RETURN>
Pump number? 1 <RETURN>
Hose number? 1 <RETURN>
Quantity? 5624.8 <RETURN>
$amount? 3217.95 <RETURN>
Hose number? <RETURN>
Pump number? 2 <RETURN>
Hose number? 2 <RETURN>
Quantity? 2345.9 <RETURN>
$amount? 6789.10 <RETURN>
Hose number? <RETURN>
Pump number? <RETURN>
R*