Using the cut charts, Estimated kerf-width compensation, Using the cut charts ‑2 – Hypertherm HRT User Manual

Page 38: Estimated kerf‑width compensation ‑2

Advertising
background image

OPERATION

3-2

Duramax Retrofit Torch

Operator Manual

Using the cut charts

The following sections provide cut charts for each set of mechanized consumables. A consumable

diagram with part numbers precedes each section.

The arc voltage increases as the consumables wear and the voltage setting should be increased to

maintain the correct Torch‑to‑Work Distance.

Note:

Hypertherm collected the data under laboratory test conditions using new

consumables.

Estimated kerf-width compensation

The widths in the tables on the following two pages are for reference. The data is obtained with

the “Best Quality” settings. Differences between installations and material composition may cause

actual results to vary from those shown in the tables.