Operation 3-30 duramax retrofit torch – Hypertherm HRT User Manual

Page 66

Advertising
background image

OPERATION

3-30

Duramax Retrofit Torch

Operator Manual

65 A Unshielded
Mild Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

2.0

5.0

250

0.1

6050

117

7340

117

3

0.2

5200

118

6330

118

4

0.5

4250

118

5250

118

6

2550

120

3560

120

8

1620

123

2230

121

10

6.0

300

0.7

970

127

1500

122

12

Edge Start

760

129

1140

124

16

500

134

650

129

20

280

138

400

133

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

16 GA

0.08

0.20

250

0.1

255

116

308

117

10 GA

190

118

232

118

3/16

0.2

135

119

172

119

1/4

0.5

90

120

116

120

3/8

0.24

300

0.7

40

126

62

122

1/2

Edge Start

27

130

40

125

5/8

20

134

26

129

3/4

13

137

18

132

Advertising
This manual is related to the following products: