Torch‑to‑work dis tance for the following cut chart is 1/16 in (1.5 mm) for all cuts.

Mild steel

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

60

134

0

16 Ga

1.5

502

12751

627

15926

134

10 Ga

3.4

211

5359

264

6706

138

0.25

1/4

6.4

86

2184

132

3353

141

0.75

3/8

9.5

41

1041

63

1600

141

1.50

1/2

12.7

27

686

42

1067

147

5/8

15.9

20

512

31

787

153

3/4

19.0

14

363

22

559

Stainless steel

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

60

134

0

16 Ga

1.5

406

10312

625

15875

136

0.25

10 Ga

3.4

159

4039

244

6198

139

0.50

1/4

6.4

72

1829

110

2794

145

0.75

3/8

9.5

34

864

53

1346

146

2.00

1/2

12.7

23

584

35

889

149

5/8

15.9

17

429

26

660

154

3/4

19.0

12

297

18

457

Aluminum

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

60

135

0

1/16

1.6

433

10995

666

16916

138

0.25

1/8

3.2

260

6604

400

10160

141

1/4

6.4

94

2388

145

3683

146

0.75

3/8

9.5

48

1219

74

1880

149

1.50

1/2

12.7

30

762

51

1295

153

5/8

15.9

21

545

33

838