Operation 3-12 duramax retrofit torch – Hypertherm HRT User Manual

Page 48

Advertising
background image

OPERATION

3-12

Duramax Retrofit Torch

Operator Manual

Note:

Torch‑to‑work dis tance for the following cut chart is 1/16 in (1.5 mm) for all cuts.

Mild steel

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

80

132

0.25

3/16

4.8

140

3556

216

5486

134

0.50

1/4

6.4

105

2667

161

4089

137

3/8

9.5

61

1549

94

2388

140

1/2

12.7

39

991

60

1524

145

1.0

5/8

15.9

26

660

40

1016

148

N/A

3/4

19.0

20

508

31

787

150

7/8

22.2

15

381

23

584

156

1

25.4

10

254

16

406

Stainless steel

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

80

134

0.25

3/16

4.8

140

3556

216

5486

136

0.50

1/4

6.4

103

2616

158

4013

139

0.75

3/8

9.5

54

1372

83

2108

142

1/2

12.7

33

838

50

1270

145

1.0

5/8

15.9

22

559

34

864

150

N/A

3/4

19.0

16

406

24

610

153

1

25.4

9

229

14

356

Aluminum

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

80

134

0.25

1/8

3.2

295

7493

454

11532

139

1/4

6.4

114

2896

176

4470

143

0.75

3/8

9.5

60

1524

121

3073

146

1/2

12.7

37

940

75

1905

154

N/A

3/4

19.0

19

483

37

940

Advertising