Operation 3-20 duramax retrofit torch – Hypertherm HRT User Manual

Page 56

Advertising
background image

OPERATION

3-20

Duramax Retrofit Torch

Operator Manual

45 A Shielded
Mild Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

0.5

1.5

3.8

250

0.0

9000

128

12500

126

1

9000

128

10800

128

1.5

0.1

9000

130

10200

129

2

0.3

6600

130

7800

129

3

0.4

3850

133

4900

131

4

2200

134

3560

131

6

0.5

1350

137

2050

132

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

26 GA

0.02

0.08

400

0.0

350

128

500

128

22 GA

350

128

450

128

18 GA

0.1

350

129

400

128

16 GA

350

130

400

129

14 GA

0.06

0.15

250

0.2

270

130

320

129

12 GA

0.4

190

133

216

131

10 GA

100

134

164

131

3/16

0.5

70

135

108

132

1/4

0.6

48

137

73

132