Operation 3-38 duramax retrofit torch – Hypertherm HRT User Manual
Page 74
Advertising

OPERATION
3-38
Duramax Retrofit Torch
Operator Manual
FineCut
Mild Steel
Metric
Material
Thickness
Amps
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce Delay
Time
Best Quality Settings
Cut Speed
Voltage
mm
A
mm
mm
%
seconds
mm/min
Volts
0.5
40
1.5
2.25
150
0.0
8250
78
0.6
8250
78
0.8
0.1
8250
78
1
45
0.2
8250
78
1.5
0.4
6400
78
2
4800
78
3
0.5
2750
78
4
0.6
1900
78
English
Material
Thickness
Amps
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce Delay
Time
Best Quality Settings
Cut Speed
Voltage
A
in
in
%
seconds
ipm
Volts
26 GA
40
0.06
0.09
150
0.0
325
78
24 GA
325
78
22 GA
0.1
325
78
20 GA
325
78
18 GA
45
0.2
325
78
16 GA
0.4
250
78
14 GA
200
78
12 GA
0.5
120
78
10 GA
95
78
Advertising