Operation duramax retrofit torch – Hypertherm HRT User Manual

Page 71

Advertising
background image

OPERATION

Duramax Retrofit Torch

Operator Manual

3-35

45 A Unshielded
Stainless Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

0.5

1.5

3.8

250

0.0

9000

121

12500

119

1

9000

121

10800

119

1.5

0.1

9000

121

10200

120

2

0.3

6000

122

9600

120

3

0.4

3250

123

4750

120

4

1900

128

3000

122

6

0.5

700

130

1450

124

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

26 GA

0.02

0.08

400

0.0

350

120

500

119

22 GA

350

120

450

119

18 GA

0.1

350

118

400

119

16 GA

350

121

400

120

14 GA

0.06

0.15

250

0.2

300

122

400

120

12 GA

0.4

150

121

224

120

10 GA

100

125

140

121

3/16

0.5

42

131

88

123

1/4

0.6

25

130

48

124

Advertising