OPERATION

Duramax Retrofit Torch

Operator Manual

3-21

45 A Shielded
Stainless Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

0.5

1.5

3.8

250

0.0

9000

130

12500

129

1

9000

130

10800

130

1.5

0.1

9000

130

10200

130

2

0.3

6000

132

8660

131

3

0.4

3100

132

4400

132

4

2000

134

2600

134

6

0.5

900

140

1020

139

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

26 GA

0.02

0.08

400

0.0

350

130

500

129

22 GA

350

130

450

129

18 GA

0.1

350

130

400

130

16 GA

350

130

400

130

14 GA

0.06

0.15

250

0.2

250

132

360

131

12 GA

0.4

140

132

206

131

10 GA

100

133

134

134

3/16

0.5

52

135

58

135

1/4

0.6

30

141

35

140