85 A Unshielded
Mild Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

2.0

5.0

250

0.0

7150

117

10400

116

3

0.1

6240

118

9000

117

4

0.2

5250

118

7200

117

6

0.5

3450

120

4400

119

8

2400

121

3100

121

10

1560

123

2070

122

12

6.0

300

0.7

1200

126

1600

124

16

Edge Start

820

132

930

128

20

540

137

640

132

25

320

143

400

137

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

14 GA

0.08

0.20

250

0.1

280

117

416

116

10 GA

0.2

230

118

328

117

3/16

175

119

220

118

1/4

0.5

125

120

160

119

3/8

65

122

86

122

1/2

0.24

300

0.6

42

127

56

125

5/8

Edge Start

33

131

37

128

3/4

23

136

27

131

7/8

18

140

21

134

1

12

144

15

138

Advertising