Operation 3-16 duramax retrofit torch – Hypertherm HRT User Manual

Page 52

Advertising
background image

OPERATION

3-16

Duramax Retrofit Torch

Operator Manual

65 A Shielded
Aluminum

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

1.5

3.8

250

0.1

8800

121

10300

122

3

0.2

7400

124

8800

124

4

0.5

6000

126

7350

125

6

3200

130

4400

128

8

0.7

1950

133

2750

130

10

4.5

300

1200

136

1650

132

12

1.2

1000

138

1330

136

16

Edge Start

650

143

800

141

20

380

147

560

145

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

1/16

0.06

0.15

250

0.1

365

121

428

121

1/8

280

124

336

124

1/4

0.5

105

131

152

128

3/8

0.7

50

135

68

131

1/2

0.18

300

1.2

35

139

48

138

5/8

Edge Start

26

143

32

141

3/4

16

146

24

144

Advertising