Operation 3-28 duramax retrofit torch – Hypertherm HRT User Manual

Page 64

Advertising
background image

OPERATION

3-28

Duramax Retrofit Torch

Operator Manual

85 A Unshielded
Aluminum

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

2.0

5.0

250

0.1

8700

118

11200

118

3

7350

120

9600

119

4

0.2

6000

122

8100

120

6

0.5

3300

125

4930

122

8

2350

127

3250

124

10

6.0

300

0.5

1800

128

2140

127

12

0.7

1300

133

1720

130

16

Edge Start

840

139

1130

134

20

470

144

700

138

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

1/8

0.08

0.20

250

0.2

280

120

368

119

3/16

200

123

271

120

1/4

0.5

110

126

172

122

3/8

75

127

88

126

1/2

0.24

300

0.6

45

135

62

131

5/8

Edge Start

34

139

45

134

3/4

22

143

32

137

Advertising
This manual is related to the following products: