Operation duramax retrofit torch – Hypertherm HRT User Manual

Page 63

Advertising
background image

OPERATION

Duramax Retrofit Torch

Operator Manual

3-27

85 A Unshielded
Stainless Steel

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

mm/min

Volts

mm/min

Volts

2

2.0

5.0

250

0.1

8550

117

11300

116

3

7000

118

9660

117

4

0.2

5600

118

7800

118

6

0.5

3400

120

4570

121

8

2250

121

2970

122

10

6.0

300

0.5

1430

123

1840

124

12

0.7

1000

129

1340

128

16

Edge Start

650

134

730

133

20

360

138

570

137

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

in

%

seconds

ipm

Volts

ipm

Volts

14 GA

0.08

0.20

250

0.1

340

117

452

116

10 GA

0.2

250

118

352

118

3/16

180

119

249

119

1/4

0.5

120

120

160

121

3/8

60

122

77

123

1/2

0.24

300

0.6

35

131

46

129

5/8

Edge Start

26

134

29

133

3/4

17

137

24

136

Advertising