Operation 3-24 duramax retrofit torch – Hypertherm HRT User Manual

Page 60

Advertising
background image

OPERATION

3-24

Duramax Retrofit Torch

Operator Manual

Note:

Torch‑to‑work dis tance for the following cut chart is 3/16 in (4.8 mm) for all cuts.

Mild steel

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

100

136

0.5

1/4

6.4

137

3479

210

5334

139

0.5

3/8

9.5

79

2006

122

3098

142

1.0

1/2

12.7

59

1498

91

2311

146

1.0

5/8

15.9

37

939

57

1447

150

1.5

3/4

19.0

28

711

43

1092

155

NA

1

25.4

17

431

26

660

160

1 1/4

31.8

10

254

16

406

Stainless steel

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

100

136

0.5

1/4

6.4

157

3987

241

6121

139

0.5

3/8

9.5

85

2159

131

3327

142

1.0

1/2

12.7

53

1346

81

2057

146

1.0

5/8

15.9

33

838

51

1295

150

1.5

3/4

19.0

22

558

33

838

155

NA

1

25.4

14

355

22

558

161

1 1/4

31.8

7

177

11

279

Aluminum

Arc current Arc voltage Pierce

delay

Material thickness

Recommended

cut speed

Maximum cut speed

in

mm

ipm

mm/min

ipm

mm/min

100

137

0.5

1/4

6.4

166

4216

255

6477

139

0.5

3/8

9.5

99

2514

153

3886

142

1.0

1/2

12.7

70

1778

107

2717

147

1.0

5/8

15.9

50

1270

77

1955

150

1.5

3/4

19.0

33

838

51

1295

154

NA

1

25.4

20

508

31

787

Advertising
This manual is related to the following products: