TROUBLESHOOTING GUIDE

Problem Suggestion
On Line Mode and Serial On Line
Mode:
the reader does not respond correctly to
the expected external signal end.

•

In the Genius™ software configuration
program select the OPERATING MODES
folder and check the “Reading Phase
Timeout” parameterization.

Reading:
it is not possible to read the target
barcode (always returns No Read)

•

Check synchronization of reading pulse with
object to read.

•

Is the scan line correctly positioned?

•

Place barcode in the center of scan line and
run TEST MODE (selectable by Genius™ as
Operating Modes).
If you still have troubles, check the following:

•

Is the reading distance within that allowed
(see reading diagrams)?

•

Is the Tilt angle too big?

•

Is the Skew angle less than 10° (direct
reflection)?

•

Choose the CODE tab and enable
different code types (except
Pharmacode). LENGTH = Variable.

•

Is the barcode quality sufficient?

•

If you had no success, try to perform the test
using the BARCODE TEST CHART included
with the product.

Communication:
the device is not transmitting anything to
the host.

•

Is serial cable connected?

•

Is correct wiring respected?

•

If using MAIN RS232 or RS485 interface, is
the reference ground connected to proper
SGND Main Isolated (also referred to as
GND_ISO)? Be careful that it is not
completely different from GND power ground.

•

If using C-BOX 100, be sure the RS485
termination switch is positioned to OFF.

•

Are serial host settings equivalent to serial
device setting?

Communication:
data do not appear on the terminal.

•

In the Genius™ program enable the DATA
COMMUNICATION SETTINGS/MAIN-
AUXILIARY PORT\DATA TX parameter.

Communication:
data transferred to the host are
incorrect, corrupted or incomplete.

•

In the Genius™ program select the DATA
COMMUNICATION SETTINGS/DATA
FORMAT folder and check for HEADER,
TERMINATOR, SEPARATOR and FILL
CHAR values.

•

Check the CODE FIELD LENGTH value, too.

•

Are the COM port parameters correctly
assigned?